Autotrol® ReadySoft™
System
Features and
Operation The Autotrol ReadySoft
alternating and high flow systems are sophisticated twin-tank
designs, created for efficiency and convenience in a variety of
applications. Incorporating an intelligent microprocessor control
and water meter, the ReadySoft systems electronically monitor water
usage and regenerate each valve at the appropriate time to provide
an uninterrupted supply of treated water. The ReadySoft system’s
ease of operation is equaled only by the uncommon reliability of the
Autotrol series 255 valve with its simple design and reinforced
Noryl* construction. Each of the ReadySoft systems operate using
two control valves connected by a manifold system. The main control,
equipped with an easy-to-read, six-digit LED display and interface
buttons, is used to program the system and provide operating
instructions to the secondary control. While regeneration is
initiated automatically when the resin bed is exhausted, the cycles
of regeneration, such as Back-Wash, Slow Rinse, and Fast Rinse, can
be adjusted to meet a wide variety of water challenges. In addition,
salt settings and capacities may be programmed to fine-tune the
operation and efficiency of the system. Water usage information
measured by the ReadySoft control system is stored in the main
controller’s non-volatile memory and can be easily accessed. This
allows for an in-depth look at the application through a wide
variety of water usage and operational information including:
Total water used since installation Average daily
water usage for each day of the week Days since last
regeneration Peak flow rate Time of day peak
flow rate occurred
ReadySoft Alternating
System For use in residential and light
commercial applications, the ReadySoft alternating system measures
water flow through a flow meter in the outlet piping. During
operation, when capacity of the on-line tank is reached, the main
control switches the tank in standby into operation and places the
on-line tank into regeneration. After completing the regeneration
the tank stops in the standby position until the on-line tank
becomes exhausted. Prior to coming on-line, the control valve in
standby performs an automatic fast rinse to drain, cleansing the
tank and removing any residual regenerant. During normal operation
the main control displays the Capacity Remaining and Flow Rate for
the on-line tank.
ReadySoft High Flow
System The ReadySoft high flow system is a parallel system that can
provide in excess of 25 gpm of service water at peak conditions. The
system measures water flow with a flow meter in the outlet piping.
The control will monitor the water usage and allocate half of the
total to each tank. When one tank reaches its capacity it will go
into regeneration and all of the service flow will be allocated to
the on-line tank. Once the regeneration of this tank is complete the
control decides whether or not to regenerate the other tank and will
go through the same process if needed. Regeneration can be initiated
at a defined time or immediately upon bed exhaustion. During normal
operation the main control will display the Capacity of tank 1,
Capacity of tank 2, and Flow Rate.
Autotrol®
Performa™ CV Filter Valve 942F/962F/962FTC
High quality granular activated carbon for de-chlorination and
VOC removal.
With the 440i clock timer control on the 163 filter valve, back
washing of your water conditioning system can be automatically or
manually initiated at any time of the day. The timer is available in
six- or seven-day options. Back-wash frequency for filtration is
easily set by positioning pins on the skipper wheel. Time of day is
programmed with a 24-hour timer knob. Manual back-wash can be
initiated if a power failure or unusually high water use occurs.
Flapper-type valves are vertically oriented to keep the sealing
surface clean. Three-cycle operation automatically handles all types
of media filters. Simple design and rugged construction ensures
built-in reliability and maximum life. Bypass water is automatically
available during regeneration. Optional auxiliary back-wash valve,
with just one moving part, boosts back-wash flow rates for heavier
media.
Autotrol®960 Demand Control Water Softener Valve
The 960 control is capable of handling almost any
application, with its fully programmable cycle times and other
features, including: NOVRAM memory and an optional battery,
which ensure the safety of the programmed data and water-usage
history Availability of manual regeneration or back-to-back
regeneration options Large, four-digit LED display and
over-sized, easy-to-push buttons for simple programming and
adjustment Memory of daily water-usage patterns to eliminate
hard-water breakthrough For the ultimate in water-conditioning
efficiency, there is simply no match for the sophisticated
microprocessor-based 960.
Home | Products | Opportunity | Contact Us Water Vending
Machine | Ozone Bottle
Rinser
| Reverse
Osmosis | Bottle Washer & Filler Commercial Bottle Washer | Filling
Station | Water
Softener | Carbon
Filter | UV
Sterilizer | Water Storage Tank | Pumps
Tel 250.490.8799 Fax
250.490.9103 |